Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC

Model: MTR105 | Order No: 1010-361 | UPC: 5036175238417

Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC

Model: MTR105 | Order No: 1010-361 | UPC: 5036175238417

Versatile and robust, this rotating machine tester is a dedicated static motor tester featuring insulation resistance tests, temperature measurement, and compensation (for IR tests). In addition, this tester features fast-detecting circuitry to reduce the chance of damage to the unit if connected to live circuits or across phases.

Versatile and robust, this rotating machine tester is a dedicated static motor tester featuring insulation resistance tests, temperature measurement, and compensation (for IR tests). In addition, this tester features fast-detecting circuitry to reduce the chance of damage to the unit if connected to live circuits or across phases.

Regular Price $2970.00 USD
Availability 5 to 6 Weeks
Quantity

Traceable In-House Calibration Certificate for your MTR105 Rotating Machine Tester

Traceable In-House Calibration Certificate for your MTR105 Rotating Machine Tester

Megger MTR105 Offers

Ideal for many applications, this rotating machine tester features a guard terminal, to eliminate any surface leakage current and detachable test leads with interchangeable clips and probes. Additionally, test results can be downloaded to a USB storage device, which can be accessed by connecting to a PC.

Features

  • Full colour graphic display
  • 3 Phase insulation resistance
  • Temperature correction for insulation resistance
  • Guard terminal
  • DLRO four wire kelvin
  • Continuity and diode test
  • Motor direction of rotation
  • Capacitance and inductance
  • CAT III 600 V up to 3000 m
  • Environmental protection to IP54
  • Guard terminal, to eliminate any surface leakage current
  • Detachable test leads with interchangeable clips and probes for different applications
  • Stores test results for up to 256 motors, which can be downloaded to a USB mass storage device
  • Rotary dial control, full graphic display, simple and easy to use
  • Environmental protection to IP54, providing protection against moisture and dust ingress, including the battery and fuse compartment
  • Tough housing: A rubber over moulding combines a tough shock absorbing outer protection with excellent grip, on a strong modified ABS housing, providing a robust case

Safety

  • Designed to be exceptionally safe to use. The fast detecting circuitry reduces the likelihood of damage to the instrument if accidentally connected to live circuits or across phases.
  • Meets the international requirements of IEC61010 and IEC61557
  • Live circuit detection and test inhibit on all measurements with user notification (except for direction of rotation measurements)
  • User selectable insulation test terminal lockout voltage 25 V, 30 V, 50 V, 75 V (default is 50 V)
  • Detection and inhibit functions when the protection fuse has failed
  • Suitable for use on CAT III applications and supply voltages to 600 V

Insulation Resistance Tests

  • Resistance range 100 Ω up to 200 GΩ
  • Supports PI, DAR, timed and temperature compensation
  • Stabilised insulation test voltage accurate to -0% +2% ±2 V, which provides a more accurate test voltage without the risk of over-voltage damage to circuits or components, the output voltage is maintained between 0 and 2% throughout the test range
  • Where a nonstandard test voltage is required, a variable range allows the exact test voltage to be selected from 10 V up to 999 V and is subject to the same stabilised output control
  • Dedicated buzzer button either ON, VISUAL or OFF
  • Adjustable buzzer for minimum resistance limit (0.5 up to 1000 MΩ)
  • Buzzer sounds on test pass

Voltmeter

  • Measures AC 10 mV up to 1000 V; DC 0 to 1000 V; True RMS (15 up to 400 Hz)
  • Three phase supply and direction of rotation

Continuity (Resistance) Tests

  • Single automatic resistance range from 0.01 Ω to 1 MΩ
  • Automatic test current selection uses the preferred test current for the load resistance under test (200 mA up to 4 Ω)
  • Bi-directional tests option automatically reverses the current without reconnecting leads
  • Lead resistance compensation (NULL) operates up to 10 Ω of resistance
  • Dedicated buzzer switch either ON, VISUAL or OFF
  • Adjustable buzzer for maximum resistance limit (1 to 200 Ω in 12 steps)
  • Buzzer sounds on test pass

DLRO Four Wire Kelvin Low Resistance

  • Automatic resistance range from 1 mΩ up to 10 Ω
  • Selectable auto or manual test
  • Bi-direction or single direction
  • Bi-directional tests option automatically reverses the current without reconnecting leads
  • 200 mA test current

Motor Direction of Test

Tests the direction of rotation of the motor under test and displays the phase sequence on screen. The connected motor is rotated in one direction and the display shows sequence of the phases of rotation. The motor is next rotated in the opposite direction, the phases are checked again and shown on the display.

Inductance, Capacitance and Resistance Meter (LCR)

Auto inductive, capacitive and resistive test. Frequency selectable to 120 or 1000 Hz. In AUTO mode, the unit automatically determines if the main element of the load is inductive, capacitive or resistive and displays the result on screen. Selectable inductance and capacitance test.

Temperature

Temperature measurement of unit under test, via the supplied thermocouple, allows temperature compensation to be applied in insulation resistance tests.

Display

Full colour graphic display makes the MTR105 simple to understand and easy to use.

Guard Terminal

The guard terminal (G) is a third terminal on the connection panel. Connection of the guard terminal, on certain applications, provides a return path for parallel leakage currents, which could otherwise create significant errors in the insulation measurement. This is especially so for surface contamination of equipment or cables.

Storage and Download of Results

Test results can be downloaded to a USB mass storage device, which can be accessed by connecting to a PC or a Laptop running PowerDB.

Instrument Software Updates

Occasional information bulletins and software updates may be issued on the web site.

Applications

  • Production tests for new manufactured motors and generators
  • Test repaired and refurbished motors and generators
  • Monitoring and maintenance of in service motors (off line) in the field
  • Utilities: Electrical power generation, water, oil/gas
  • Industrial: Production line / factory maintenance teams
  • HVAC field engineers
  • OEM: Motors/generators
  • Service: Motor repair workshops
  • Transport: Rail, electric vehicles, marine, etc

Megger MTR105 Specifications

Insulation Resistance Volts/Accuracy:
50 V; 10 GΩ ±2% ±2 digits ±4.0% per GΩ
100 V; 20 GΩ ±2% ±2 digits ±2.0% per GΩ
250 V; 50 GΩ ±2% ±2 digits ±0.8% per GΩ
500 V; 100 GΩ ±2% ±2 digits ±0.4% per GΩ
1000 V; 200 GΩ ±2% ±2 digits ±0.2% per GΩ

Polarisation index (PI): 10 minute/1 minute ratio
Dielectric absorption ratio (DAR): User configurable 15 seconds or 30 seconds t1 start time with t2 fixed at 60 seconds
Guard terminal performance: <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
Resolution: 0.1 kΩ
Short circuit/charge current: 2 mA +0% -50% (IEC61557-2)
Terminal voltage accuracy: -0% +2% ±2 V
Test current: 1 mA at minimum pass value of insulation to a maximum of 2 mA
Operation range: 0.10 MΩ to 1.0 GΩ (IEC61557-2)
Leakage current display: 0.1 uA resolution 10% (±3 digits)
Voltage display: ±3% ±2 digits ±0.5% of rated voltage
Note: Above specifications only apply when high quality silicone leads are being used - as supplied with the instrument.
Continuity Measurement: 0.01 Ω to 1 MΩ (0 to 1000 kΩ analogue scale)
Accuracy: ±3% ±2 digits (0 to 99.9 Ω); ±5% ±2 digits (100 Ω to 500 kΩ)
Test current: 200 mA (-0 mA +20 mA), 0.01 to 4 Ω
Polarity: Single or Dual (factory default) polarity
Lead resistance: Null up to 10 Ω
Selectable current limit: 20 and 200 mA
Capacitance Range: 0.1 nF to 1 mF
Accuracy: ±5.0% ±2 digits (1 nF to 10 μF)
Voltmeter Range: DC: 0 to 1000 V, AC: 10 mV to 1000 V, TRMS sinusoidal (15 to 400 Hz)
Accuracy: DC ± 2% ±2 digits (0 to 1000 V), AC: ± 2% ±2 digits (10 mV to 1000 V TRMS)
Frequency range: 15 - 400 Hz (50 mV to 1000 V)
Frequency resolution: 0.1 Hz
Frequency accuracy ±0.5% ±1 digit
Diode Test: Diode test accuracy: ±2% ±2 digits, 0.01 to 3 V
Display range: 0 to 3 V
Temperature Measurement and Compensation Thermocouple: Type T (Type K and Type J)
Thermocouple range: 4 to 392°F (-20 to 200°C)
Instrument range: 4 to 1832°F (-20 to 1000°C)
Instrument resolution: 0.18°F (0.1°C)
Instrument accuracy: ±1.8°F ±20 digits (1°C). Basic accuracy stated assumes forward and reverse measurements.
DLRO Four Wire Kelvin Low Resistance Test current: 200 mA DC
Range: 1 mΩ to 10 Ω
Resolution: 0.01 mΩ
Accuracy: ±0.25% rdg. ±10 digits, accuracy stated includes forward and reverse measurements.
Inductance (Instrument Accuracy) Range: 1 H, 200 mH, 20 mH, 2 mH
Accuracy [+(Lx/10000)% +5 digits)]: ±0.7%, ±1%, ±0.7%, ±2%, ±1.2%, ±2%
Test frequency: 1 kHz, 120 Hz, 1 kHz, 120 Hz, 1 kHz, 1 kHz only
Results Storage Storage capacity: 256 motor results (date/time stamped)
Data download: USB Type A (USB Mass Storage Device)
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -13 to 122°F (-25 to 50°C)
Calibration: 68°F (20°C)
Humidity 90% RH at 104°F (40°C) maximum
Maximum Altitude 9843' (3000 m)
IP rating IP54
Display Full LCD colour screen with user configurable backlight
Power Battery: 6 x IEC LR6 1.5 V Alkaline (AA)
Battery life: 10 motors per (complete suite of tests at 100 V into 100 MΩ) IEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 s testing on 25 s standby at 500 V into 0.5 MΩ. IEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 s testing on 25 s standby on 1 Ω resistance.
Safety protection: IEC61010-1 CAT III 600 V
EMC Industrial: IEC61326
Temperature coefficien:t <0.1% per °C up to 1 GΩ
Dimensions 8.98 x 4.1 x 2.95" (228 x 105 x 75 mm)
Weight 2.02 lbs (0.93 kg)
Click here for complete specifications on the Megger MTR105

What's included with the Megger MTR105

  • Rotating Machine Tester
  • Calibration Certificate
  • Temperature Probe
  • IR Lead Set
  • Kelvin Clip Lead Set
  • USB Memory Stick
  • Hook Strap Assembly
  • Soft Pouch
  • 6 x AA Batteries
  • Quick Start Guide

Getting to know the Megger MTR105 Rotating Machine Tester


Rotating machines are highly important assets in power generation and industrial applications. Machine reliability and availability are crucial to ensure a reliable power supply. Premature failure may lead to significant economic losses, due to unexpected outages and possible damage to the asset itself.

The Megger MTR105 Rotating Machine Tester incorporates temperature measurement and compensation (for IR tests), the motor direction of rotation plus supply phase rotation tests. These new test abilities make the MTR105 a real-world, versatile, handheld motor test instrument.

This tester is capable of measuring:
Insulation Resistance - see 0:16
Voltmeter - see 0:27
Continuity (Resistance) - see 0:32
DLRO (Digital Low Resistance Ohmmeter) - see 0:37
Motor Direction of Rotation - see 0:48
Inductance, Capacitance and Resistance Meter (LCR) - see 0:54
Temperature - see 1:01

Find out exactly how each of these measurements can benefit you in the field by watching the video!

Click on a category to view a selection of compatible accessories with the Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC.

Megger 1012-068 Hook Strap Assembly for the MTR105 1012-068
For use with the MTR105 Rotating Machine Tester.




Megger 1012-064 Kelvin Probe Pins, 4-pack 1012-064
For use with the MTR105 rotating tester when performing Kelvin low resistance tests.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Megger 1000-355 Fuse Pack, spare, 5-pack, 500 mA FF 1 kV 1000-355
For use with the MTR105 rotating tester.




Megger 1012-067 Temperature Probe, T type, CAT III 600 V 1012-067
Ideal for measuring low temperatures, this T-type temperature probe is for use with the MTR105 rotating machine tester.




Megger 1007-157 SP5 Remote Switch Probe, CATIV, 600V 1007-157
For use with MIT400/2 Series of Insulation Testers.




Megger 1012-065 Test Probe Set, long reach, CAT II 1000 V 1012-065
Comes equipped with a long reach and is CAT III 1000 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-066 Test Probe Set, long reach, CAT IV 600 V 1012-066
Comes equipped with a long reach and is rated CAT IV 600 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-069 Grabber Clip Lead Set, CAT III 100 V, CAT IV 600 V 1012-069
For use with the MTR105 rotating tester.




Megger 1011-928 Kelvin Clip Lead Set, CAT III 600 V 1011-928
For use with the MTR105 rotating tester when performing Kelvin low resistance tests. Additionally, it comes equipped with two clip leads, four 4 mm right-angled connectors, and single (2-core) cable.




Megger 1011-929 Kelvin Probe Lead Set, CAT III 600 V 1011-929
For use with the MTR105 rotating tester when performing Kelvin low resistance tests.




Megger 1012-063 Soft Pouch for the MTR105 1012-063
Ideal for transporting and protecting, this soft pouch is for use with the MTR105 rotating machine tester.




Ask a question about Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC

Customer Reviews for the Megger MTR105

Megger MTR105 Offers

Ideal for many applications, this rotating machine tester features a guard terminal, to eliminate any surface leakage current and detachable test leads with interchangeable clips and probes. Additionally, test results can be downloaded to a USB storage device, which can be accessed by connecting to a PC.

Features

  • Full colour graphic display
  • 3 Phase insulation resistance
  • Temperature correction for insulation resistance
  • Guard terminal
  • DLRO four wire kelvin
  • Continuity and diode test
  • Motor direction of rotation
  • Capacitance and inductance
  • CAT III 600 V up to 3000 m
  • Environmental protection to IP54
  • Guard terminal, to eliminate any surface leakage current
  • Detachable test leads with interchangeable clips and probes for different applications
  • Stores test results for up to 256 motors, which can be downloaded to a USB mass storage device
  • Rotary dial control, full graphic display, simple and easy to use
  • Environmental protection to IP54, providing protection against moisture and dust ingress, including the battery and fuse compartment
  • Tough housing: A rubber over moulding combines a tough shock absorbing outer protection with excellent grip, on a strong modified ABS housing, providing a robust case

Safety

  • Designed to be exceptionally safe to use. The fast detecting circuitry reduces the likelihood of damage to the instrument if accidentally connected to live circuits or across phases.
  • Meets the international requirements of IEC61010 and IEC61557
  • Live circuit detection and test inhibit on all measurements with user notification (except for direction of rotation measurements)
  • User selectable insulation test terminal lockout voltage 25 V, 30 V, 50 V, 75 V (default is 50 V)
  • Detection and inhibit functions when the protection fuse has failed
  • Suitable for use on CAT III applications and supply voltages to 600 V

Insulation Resistance Tests

  • Resistance range 100 Ω up to 200 GΩ
  • Supports PI, DAR, timed and temperature compensation
  • Stabilised insulation test voltage accurate to -0% +2% ±2 V, which provides a more accurate test voltage without the risk of over-voltage damage to circuits or components, the output voltage is maintained between 0 and 2% throughout the test range
  • Where a nonstandard test voltage is required, a variable range allows the exact test voltage to be selected from 10 V up to 999 V and is subject to the same stabilised output control
  • Dedicated buzzer button either ON, VISUAL or OFF
  • Adjustable buzzer for minimum resistance limit (0.5 up to 1000 MΩ)
  • Buzzer sounds on test pass

Voltmeter

  • Measures AC 10 mV up to 1000 V; DC 0 to 1000 V; True RMS (15 up to 400 Hz)
  • Three phase supply and direction of rotation

Continuity (Resistance) Tests

  • Single automatic resistance range from 0.01 Ω to 1 MΩ
  • Automatic test current selection uses the preferred test current for the load resistance under test (200 mA up to 4 Ω)
  • Bi-directional tests option automatically reverses the current without reconnecting leads
  • Lead resistance compensation (NULL) operates up to 10 Ω of resistance
  • Dedicated buzzer switch either ON, VISUAL or OFF
  • Adjustable buzzer for maximum resistance limit (1 to 200 Ω in 12 steps)
  • Buzzer sounds on test pass

DLRO Four Wire Kelvin Low Resistance

  • Automatic resistance range from 1 mΩ up to 10 Ω
  • Selectable auto or manual test
  • Bi-direction or single direction
  • Bi-directional tests option automatically reverses the current without reconnecting leads
  • 200 mA test current

Motor Direction of Test

Tests the direction of rotation of the motor under test and displays the phase sequence on screen. The connected motor is rotated in one direction and the display shows sequence of the phases of rotation. The motor is next rotated in the opposite direction, the phases are checked again and shown on the display.

Inductance, Capacitance and Resistance Meter (LCR)

Auto inductive, capacitive and resistive test. Frequency selectable to 120 or 1000 Hz. In AUTO mode, the unit automatically determines if the main element of the load is inductive, capacitive or resistive and displays the result on screen. Selectable inductance and capacitance test.

Temperature

Temperature measurement of unit under test, via the supplied thermocouple, allows temperature compensation to be applied in insulation resistance tests.

Display

Full colour graphic display makes the MTR105 simple to understand and easy to use.

Guard Terminal

The guard terminal (G) is a third terminal on the connection panel. Connection of the guard terminal, on certain applications, provides a return path for parallel leakage currents, which could otherwise create significant errors in the insulation measurement. This is especially so for surface contamination of equipment or cables.

Storage and Download of Results

Test results can be downloaded to a USB mass storage device, which can be accessed by connecting to a PC or a Laptop running PowerDB.

Instrument Software Updates

Occasional information bulletins and software updates may be issued on the web site.

Applications

  • Production tests for new manufactured motors and generators
  • Test repaired and refurbished motors and generators
  • Monitoring and maintenance of in service motors (off line) in the field
  • Utilities: Electrical power generation, water, oil/gas
  • Industrial: Production line / factory maintenance teams
  • HVAC field engineers
  • OEM: Motors/generators
  • Service: Motor repair workshops
  • Transport: Rail, electric vehicles, marine, etc

Megger MTR105 Specifications

Insulation Resistance Volts/Accuracy:
50 V; 10 GΩ ±2% ±2 digits ±4.0% per GΩ
100 V; 20 GΩ ±2% ±2 digits ±2.0% per GΩ
250 V; 50 GΩ ±2% ±2 digits ±0.8% per GΩ
500 V; 100 GΩ ±2% ±2 digits ±0.4% per GΩ
1000 V; 200 GΩ ±2% ±2 digits ±0.2% per GΩ

Polarisation index (PI): 10 minute/1 minute ratio
Dielectric absorption ratio (DAR): User configurable 15 seconds or 30 seconds t1 start time with t2 fixed at 60 seconds
Guard terminal performance: <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
Resolution: 0.1 kΩ
Short circuit/charge current: 2 mA +0% -50% (IEC61557-2)
Terminal voltage accuracy: -0% +2% ±2 V
Test current: 1 mA at minimum pass value of insulation to a maximum of 2 mA
Operation range: 0.10 MΩ to 1.0 GΩ (IEC61557-2)
Leakage current display: 0.1 uA resolution 10% (±3 digits)
Voltage display: ±3% ±2 digits ±0.5% of rated voltage
Note: Above specifications only apply when high quality silicone leads are being used - as supplied with the instrument.
Continuity Measurement: 0.01 Ω to 1 MΩ (0 to 1000 kΩ analogue scale)
Accuracy: ±3% ±2 digits (0 to 99.9 Ω); ±5% ±2 digits (100 Ω to 500 kΩ)
Test current: 200 mA (-0 mA +20 mA), 0.01 to 4 Ω
Polarity: Single or Dual (factory default) polarity
Lead resistance: Null up to 10 Ω
Selectable current limit: 20 and 200 mA
Capacitance Range: 0.1 nF to 1 mF
Accuracy: ±5.0% ±2 digits (1 nF to 10 μF)
Voltmeter Range: DC: 0 to 1000 V, AC: 10 mV to 1000 V, TRMS sinusoidal (15 to 400 Hz)
Accuracy: DC ± 2% ±2 digits (0 to 1000 V), AC: ± 2% ±2 digits (10 mV to 1000 V TRMS)
Frequency range: 15 - 400 Hz (50 mV to 1000 V)
Frequency resolution: 0.1 Hz
Frequency accuracy ±0.5% ±1 digit
Diode Test: Diode test accuracy: ±2% ±2 digits, 0.01 to 3 V
Display range: 0 to 3 V
Temperature Measurement and Compensation Thermocouple: Type T (Type K and Type J)
Thermocouple range: 4 to 392°F (-20 to 200°C)
Instrument range: 4 to 1832°F (-20 to 1000°C)
Instrument resolution: 0.18°F (0.1°C)
Instrument accuracy: ±1.8°F ±20 digits (1°C). Basic accuracy stated assumes forward and reverse measurements.
DLRO Four Wire Kelvin Low Resistance Test current: 200 mA DC
Range: 1 mΩ to 10 Ω
Resolution: 0.01 mΩ
Accuracy: ±0.25% rdg. ±10 digits, accuracy stated includes forward and reverse measurements.
Inductance (Instrument Accuracy) Range: 1 H, 200 mH, 20 mH, 2 mH
Accuracy [+(Lx/10000)% +5 digits)]: ±0.7%, ±1%, ±0.7%, ±2%, ±1.2%, ±2%
Test frequency: 1 kHz, 120 Hz, 1 kHz, 120 Hz, 1 kHz, 1 kHz only
Results Storage Storage capacity: 256 motor results (date/time stamped)
Data download: USB Type A (USB Mass Storage Device)
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -13 to 122°F (-25 to 50°C)
Calibration: 68°F (20°C)
Humidity 90% RH at 104°F (40°C) maximum
Maximum Altitude 9843' (3000 m)
IP rating IP54
Display Full LCD colour screen with user configurable backlight
Power Battery: 6 x IEC LR6 1.5 V Alkaline (AA)
Battery life: 10 motors per (complete suite of tests at 100 V into 100 MΩ) IEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 s testing on 25 s standby at 500 V into 0.5 MΩ. IEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 s testing on 25 s standby on 1 Ω resistance.
Safety protection: IEC61010-1 CAT III 600 V
EMC Industrial: IEC61326
Temperature coefficien:t <0.1% per °C up to 1 GΩ
Dimensions 8.98 x 4.1 x 2.95" (228 x 105 x 75 mm)
Weight 2.02 lbs (0.93 kg)
Click here for complete specifications on the Megger MTR105

What's included with the Megger MTR105

  • Rotating Machine Tester
  • Calibration Certificate
  • Temperature Probe
  • IR Lead Set
  • Kelvin Clip Lead Set
  • USB Memory Stick
  • Hook Strap Assembly
  • Soft Pouch
  • 6 x AA Batteries
  • Quick Start Guide

Getting to know the Megger MTR105 Rotating Machine Tester


Rotating machines are highly important assets in power generation and industrial applications. Machine reliability and availability are crucial to ensure a reliable power supply. Premature failure may lead to significant economic losses, due to unexpected outages and possible damage to the asset itself.

The Megger MTR105 Rotating Machine Tester incorporates temperature measurement and compensation (for IR tests), the motor direction of rotation plus supply phase rotation tests. These new test abilities make the MTR105 a real-world, versatile, handheld motor test instrument.

This tester is capable of measuring:
Insulation Resistance - see 0:16
Voltmeter - see 0:27
Continuity (Resistance) - see 0:32
DLRO (Digital Low Resistance Ohmmeter) - see 0:37
Motor Direction of Rotation - see 0:48
Inductance, Capacitance and Resistance Meter (LCR) - see 0:54
Temperature - see 1:01

Find out exactly how each of these measurements can benefit you in the field by watching the video!

Click on a category to view a selection of compatible accessories with the Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC.

Megger 1012-068 Hook Strap Assembly for the MTR105 1012-068
For use with the MTR105 Rotating Machine Tester.




Megger 1012-064 Kelvin Probe Pins, 4-pack 1012-064
For use with the MTR105 rotating tester when performing Kelvin low resistance tests.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Megger 1000-355 Fuse Pack, spare, 5-pack, 500 mA FF 1 kV 1000-355
For use with the MTR105 rotating tester.




Megger 1012-067 Temperature Probe, T type, CAT III 600 V 1012-067
Ideal for measuring low temperatures, this T-type temperature probe is for use with the MTR105 rotating machine tester.




Megger 1007-157 SP5 Remote Switch Probe, CATIV, 600V 1007-157
For use with MIT400/2 Series of Insulation Testers.




Megger 1012-065 Test Probe Set, long reach, CAT II 1000 V 1012-065
Comes equipped with a long reach and is CAT III 1000 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-066 Test Probe Set, long reach, CAT IV 600 V 1012-066
Comes equipped with a long reach and is rated CAT IV 600 V. Additionally, this test probe set is for use with the MTR105 rotating machine tester.




Megger 1012-069 Grabber Clip Lead Set, CAT III 100 V, CAT IV 600 V 1012-069
For use with the MTR105 rotating tester.




Megger 1011-928 Kelvin Clip Lead Set, CAT III 600 V 1011-928
For use with the MTR105 rotating tester when performing Kelvin low resistance tests. Additionally, it comes equipped with two clip leads, four 4 mm right-angled connectors, and single (2-core) cable.




Megger 1011-929 Kelvin Probe Lead Set, CAT III 600 V 1011-929
For use with the MTR105 rotating tester when performing Kelvin low resistance tests.




Megger 1012-063 Soft Pouch for the MTR105 1012-063
Ideal for transporting and protecting, this soft pouch is for use with the MTR105 rotating machine tester.




Ask a question about Megger MTR105 Rotating Machine Tester, 100 Ω to 200 GΩ, 10 mV to 1000 V AC/0 to 1000 V DC

Customer Reviews for the Megger MTR105

More Megger Products

How to Effectively Protect and Maintain Wind Turbines
Calibration Lab